Highjoule integrated Battery Energy Storage Systems provide a mature turnkey solution for commercial & industrial clients seeking reliable backup power & optimized energy management.
| Gerð | HJ-G125-261L |
|---|---|
| DC hliðarfæribreytur | |
| Gerð klefa | LFP 3.2V / 314Ah |
| Orkumat | 261kWh |
| Samsettar stillingar | 1P260S |
| Voltage Range | 728-936V DC |
| Fjöldi lota | ≥6000 @25℃ |
| Dýpt losunar | 90% DOD |
| Samskipti Interface | Modbus TCP, Modbus RTU, CAN2.0 |
| Úttaksbreytur tengdar við raforkukerfi | |
| Rated framleiðsla máttur | 125kW |
| Metin rafspenna | 230/400V, 3L+N+PE |
| Hámarks straumur | 198A |
| Máttur þáttur | 0.99 |
| Tíðni nets | 50 / 60Hz |
| Heildarharmonísk straumröskun | <2% (metið afl) |
| Úttaksbreytur utan nets | |
| Rated framleiðsla máttur | 125kW |
| Málútgangsspenna | 230V / 400V |
| Tíðni nets | 50 / 60Hz |
| Max framleiðsla núverandi | 198A |
| Skiptitími utan nets | 20ms |
| Skilvirkni | |
| Hámarks skilvirkni | 99.00% |
| Kerfisbreyting | |
| Stærð (H * D * B) | 1055 * 2300 * 1300 |
| lóð | ≈2.8T |
| Verndunarstig gegn innrás | IP54 |
| Tæringarþolsflokkur | C4 |
| Rekstrarhitastig | Hleðsla: 0℃~55℃ (32 °F~131 °F) Útskrift: -20℃~55℃ (-4 °F~131 °F) |
| Rekstrar rakastig svið | 5% ~ 95% (engin þétting) |
| kælingu aðferð | Vökvakæling |
| Aðferðir við slökkvistarf | Úðahömlun á pakkningastigi |
| Hámark rekstrarhæð | ≤2000 m |
| Samskiptareglur | Modbus TCP, Modbus RTU, CAN2.0 |
| Vottunarstaðlar | |
| Öryggisvottun | IEC62619/IEC63056/IEC62477 |
| EMC vottun | CE |
| Staðall fyrir nettengingu | EN 50549-1/10 |
Athugið: Forskriftir geta breyst án fyrirvara vegna endurbóta á vöru.
Dreifð orkukerfi, stilling á hámarks- og tíðnikerfi, varaafl, örnet, orkugeymsla fyrir iðnað og fyrirtæki.
Við erum staðráðin í að veita skjótan, faglegan stuðning til að tryggja að orkuþörfum þínum sé alltaf mætt með hæsta þjónustustigi.
Við erum hér til að svara spurningum þínum og veita orkulausnir sem henta þínum þörfum best.